Desempeño de un grupo de laboratorios mexicanos en la determinación de HbA1c
| Audiencia | Público en general | es_ES |
| Cobertura | México | es_ES |
| Fecha de ingreso | 2026-09-15T00:31:14Z | |
| Fecha de publicación | 2007-01-01 | |
| Resumen | In this study, we assessed the competency of Mexican labo- ratories for glicated hemoglobin (HbA1c) measurement, becoming the first study done in the country in order to es- tablish a permanent quality assurance scheme program for HbA1c. Forty-six laboratories participated in the study, which were classified by group according to methodology and equipment used. All laboratories received two pooled samples from fresh blood obtained from six non-diabetic male donors, for sample and six diabetic males, for sample B. An aliquot from each sample was prepared ac- cording to the reference method of the International Fede- ration of Clinical Chemistry and Laboratory Medicine (IFCC). The assigned value was obtained from the Europe- an Reference Laboratory (ERL) for Glico hemoglobin. All samples were analyzed in triplicate; to estimate the diffe- rences from the mean for HbA1c between methods and equipments, ANOVA test was used. Laboratory results showed a very heterogeneous situation. For sample A, we found a mean value of 5.78 + 1.89% and a coefficient of variation (CV) of 32.7%. For sample B, the mean was 9.10 + 2.4%, and CV of 26.4%. On the other hand, in some specific laboratories optimal results were found with a CV < 2.5%. Reference values of 5.52% and 9.23% were as- signed for sample A and B, respectively. We found differ- ences for the mean value of HbA1c between methods and equipments. This study demonstrated the need to contin- ue evaluating the competence of the clinical laboratories in Mexico with the aim to improve the quality of the services provides to the patient. RESUMEN | es_ES |
| URI | https://riuat.uat.edu.mx/handle/123456789/2914 | |
| Idioma | es | es_ES |
| Editorial | Universidad Autónoma del Estado de México | es_ES |
| Relación | Redalyc (Universidad Autónoma del Estado de México) | es_ES |
| URL relacionado | https://www.redalyc.org/articulo.oa?id=57632303 | es_ES |
| Derechos | Acceso restringido / Suscripción (Metadatos de producción científica) | es_ES |
| Licencia | http://purl.org/coar/access_right/c_16ec | es_ES |
| Fuente | Redalyc (Universidad Autónoma del Estado de México) | |
| Palabra clave | Coefficient of variation | es_ES |
| Palabra clave | Medicine | es_ES |
| Palabra clave | Mean value | es_ES |
| Palabra clave | Quality assurance | es_ES |
| Palabra clave | Reference values | es_ES |
| Palabra clave | Sample (material) | es_ES |
| Palabra clave | Mathematics | es_ES |
| Palabra clave | Statistics | es_ES |
| Palabra clave | External quality assessment | es_ES |
| Palabra clave | Internal medicine | es_ES |
| Palabra clave | Chemistry | es_ES |
| Palabra clave | Chromatography | es_ES |
| Clasificación | Diabetes Management and Research | es_ES |
| Título | Desempeño de un grupo de laboratorios mexicanos en la determinación de HbA1c | es_ES |
| Tipo | Artículo | es_ES |
| Arbitrado | Ha sido Arbitrado | es_ES |
| Autor | Rojano-Rodríguez, Eduardo | |
| Autor | Ri, Acosta-González | |
| Autor | Bocanegra-Alonso, Anabel | |
| Autor | Rivera-Sánchez, G | |
| Autor | Ri, Sierra-Amor | |
| Autor | Rojano-Rodríguez, Eduardo | es_ES |
| Autor | Ri, Acosta-González | es_ES |
| Autor | Bocanegra-Alonso, Anabel | es_ES |
| Autor | Rivera-Sánchez, G | es_ES |
| Autor | Ri, Sierra-Amor | es_ES |
| Institución | Universidad Autónoma de Tamaulipas | |
| Institución | Universidad Autónoma de Tamaulipas | es_ES |
| URL relacionada | https://www.redalyc.org/articulo.oa?id=57632303 | |
| Tipo de artículo | Indexado | |
| Tipo de artículo | Indexado | es_ES |