Optical fiber reflectance sensor coupled to a multisyringe flow injection system for preconcentration and determination of 1-naphthylamine in water samples
| Audiencia | Público en general | es_ES |
| Cobertura | México[ 143] | es_ES |
| Fecha de ingreso | 2026-10-05T16:34:49Z | |
| Fecha de publicación | 2006-01-01 | |
| Resumen | A novel optical fiber reflectance sensor is coupled to a multisyringe flow injection system (MSFIA) for the preconcentration and determination of I -naphthylamine (NPA) in water samples using C 18 disks (octadecyl groups). NPA, being a first-class carcinogen, is important from a toxicological point of view and, therefore, its quantification is of considerable interest. In this study, the Griess reaction is used for sensitive and selective spectrophotometric determination of NPA. The reaction involves conversion of nitrite into nitrous acid in acidic medium followed by diazotization of sulphanilic acid and formation of a diazonium salt. The diazonium salt is then combined with NPA to form 4-(sulphophenylazo)-1-naphthylarnine, an azo dye. This compound is subsequently retained onto a C18 disk followed by spectrophotometric detection at 540nm, and it is then eluted with methanol in water (80\%, v/v), so that the C18 disk is regenerated for subsequent experiments. Under the established optimum conditions, a calibration graph for NPA was constructed. Good linearity was observed within a concentration range from 10 to 160 mu g l(-1). The lineal regression equation is A = (0.0027 +/- 0.000 1) {[}NPA] + (0.0296 +/- 0.0047), r = 0.9991; relative standard deviation values obtained from the analysis of 10 samples of 10, 80 and 160 mu g l(-1) are 4.7, 1.2 and 0.6\%, respectively. The mean value relative errors for concentrations of 10, 80, 160 mu g l-1 are 3.4, 0.9 and 0.4\%, respectively. The detection and quantification limits were 1.1 and 3.7 mu g l(-1). A sampling throughput of 14 injections per hour is achieved. The repeatability calculated for five different C 18 disks was E-rel = 2.8\%. The proposed technique has been validated by replicate analysis (n = 6) of several water samples with spiked NPA, giving satisfactory results. (c) 2006 Elsevier B.V. All rights reserved. | es_ES |
| Doi | https://doi.org/10.1016/j.aca.2005.12.049 | es_ES |
| URI | https://riuat.uat.edu.mx/handle/123456789/6307 | |
| Idioma | Inglés[20] | es_ES |
| Editorial | ELSEVIER SCIENCE BV | es_ES |
| Relación | Analytica Chimica Acta | es_ES |
| URL relacionado | https://doi.org/10.1016/j.aca.2005.12.049 | es_ES |
| Derechos | Acceso restringido / Suscripción (Metadatos de producción científica) | es_ES |
| Licencia | http://purl.org/coar/access_right/c_16ec | es_ES |
| Fuente | Analytica Chimica Acta | |
| Palabra clave | multisyringe flow injection analysis (MSFIA) | es_ES |
| Palabra clave | reflectance sensor | es_ES |
| Palabra clave | optosensor | es_ES |
| Palabra clave | 1-naphthylamine (NPA) | es_ES |
| Palabra clave | Griess reaction | es_ES |
| Palabra clave | C18 disks | es_ES |
| Palabra clave | water samples | es_ES |
| Título | Optical fiber reflectance sensor coupled to a multisyringe flow injection system for preconcentration and determination of 1-naphthylamine in water samples | es_ES |
| Tipo | Ponencia | es_ES |
| Arbitrado | Ha sido Arbitrado | es_ES |
| Autor | Mar, J. L. Guzman | |
| Autor | Lopez Martinez, L. | |
| Autor | Lopez de Alba, P. L. | |
| Autor | Castrejon Duran, J. E. | |
| Autor | Cerda Martin, V. | |
| Autor | Mar, J. L. Guzman | es_ES |
| Autor | Lopez Martinez, L. | es_ES |
| Autor | Lopez de Alba, P. L. | es_ES |
| Autor | Castrejon Duran, J. E. | es_ES |
| Autor | Cerda Martin, V. | es_ES |
| Institución | Universidad Autónoma de Tamaulipas | |
| Institución | Universidad Autónoma de Tamaulipas | es_ES |
| Número | SI | es_ES |
| Rango de páginas | 406-412 | es_ES |
| URL relacionada | https://doi.org/10.1016/j.aca.2005.12.049 | |
| Tipo de artículo | Indexado | |
| Tipo de artículo | Indexado | es_ES |
| Volumen | 573 | es_ES |
